INE7-T
Detector in explosionproof enclosure
Explosion-proof enclosure detector, similar to the INE7 series detectors, equipped with an LCD touchscreen display. Thanks to this feature, calibration, verification, and maintenance operations can be performed without opening the enclosure.
This characteristic allows safe operation even in classified environments.
The detectors from the INDUSTRIAL series are manufactured using the most modern reflow and SMT construction techniques. They use the latest generation of microprocessor technology to deliver fast response and ensure accuracy and reliability.
The sensitive element is connected to an interchangeable device component which allows installers to replace the sensor cap (the part susceptible to wear and tear) without needing to recalibrate the device.
The complete product line includes a wide array gas leak detectors, all available in explosionproof or dustproof enclosures to satisfy even the most exacting requirements.
During the installation phase or maintenance sessions, you can interface INDUSTRIAL series detectors with a PC (via an INA55-700 interface) or Android Smartphone (via an INA55-701 interface) in order to configure the parameters, change the intervention thresholds, check the gas-level readings and/or simulate alarm, pre-alarm and fault conditions.
- Selectable delays from 0 to 240 seconds for each individual threshold.
- Reading compensation system in accordance with ambient temperature.
- Replacement of sensor cap directly on-site without need of titrated gas canisters.
- Connection to PC (via INA55-700 interface) or Android SmartPhone (via INA55-700 interface) for threshold, filter and delay settings, real-time Value Readings and simulation of alarm, pre-alarm and fault conditions.
Orders for Detectors must specify not only the type of enclosure, but also the type of gas, the technology of the sensitive element and the type of output interface. Following is a schematic representation of the order codes.
TECHNICAL SPECIFICATIONS | ||
Power supply voltage | 11 – 30 Vdc | |
Standby current consumption | Semiconductor sensors | 50 mA |
Catalytic sensors | 70 mA | |
Electrochemical sensors | 30 mA | |
Alarm current consumption | Semiconductor sensors | 80 mA |
Catalytic sensors | 100 mA | |
Electrochemical sensors | 60 mA | |
Operating temperature | 0 ... + 40 °C | |
Weight | IP55 enclosure | 370 g |
ATEX enclosure | 1000g | |
Dimensions | IP55 enclosure | 141x100x60 mm |
ATEX enclosure | 165x90x80 mm | |
Maximum ambient air speed in the protected ambient | 10 m/S |
Following is a schematic representation of the order codes.
IN Suffix |
IN |
G = IP55 enclosure / E = ATEX enclosure |
h |
Industrial series (7) |
7 |
Type of GAS (see table 1) |
nn |
Detector technology (see table 2) |
t |
Hyphen |
- |
Type of interface (see table 3) |
ii |
Table 1 | ||
Code nn |
Gas detected |
Pre-set Pre-alarm/Alarm thresholds |
00 |
Methane (CH4) |
15/30 % L.I.E. |
01 |
Special Gas (see Order Code Table) |
15/30 % L.I.E. |
02 |
Petrol fumes |
15/30 % L.I.E. |
03 |
Carbon monoxide (CO) |
100 / 200 PPM |
04 |
Hydrogen (H2) |
15/30 % L.I.E. |
05 |
LPG (Liquid Petroleum Gas) |
15/30 % L.I.E. |
06 |
Propane |
15/30 % L.I.E. |
07 |
Ammonia (Pre-alarm at 100 PPM, Alarm at 200 PPM) |
100 / 200 PPM |
08 |
Ammonia (Pre-alarm at 1000 PPM, Alarm at 2000 PPM) |
1000 / 2000 PPM |
09 |
Acetylene |
15/30 % L.I.E. |
10 |
Oxygen (Excess) |
24% / 27% |
11 |
Oxygen (Lack) |
18% / 15% |
Table 2 | |
Code t |
Technology of sensitive element of detector |
S |
Semiconductor |
C |
Catalytic |
H |
Electrochemical cell |
Table 3 | |
Code ii |
Type of interface |
RL |
3 Relays (Alarm, Pre-alarm and fault) |
AS-C |
Connection with conventional line (provides Pre-alarm, Alarm, Fault signalling. One detector only per line) |
AS-M |
Connection for addressable Input module - Inim model EM312SR |
42 |
4-20 mA module |
LE |
Direct connection to Inim Loop |