IB200/A
BUS isolator with data and power-supply regeneration and tamper protection
The enhanced version, IB200/A, protects and regenerates the BUS data signals and its power supply. Using an isolator limits BUS trouble caused by eventual anomaly (short-circuit, tamper) to the isolator-protected section and simplifies identification of it the section involved. As a result of the regeneration feature, fitting an isolator to the BUS also allows you to extend its length.
The IB200/A is also useful safeguard against acts of vandalism acts to peripherals located in non-protected areas. If a peripheral is damaged and the operating capacity of the BUS is at risk, the isolator, installed in the protected area will guarantee the functionality of the rest of the system.
The BUS is without doubt one of the most important components of any antintrusion control panel.
It is the “backbone” of the system, in fact, the BUS carries information from the control panel to the system peripherals and vice versa. Therefore, if the system is to provide maximum reliability, then the BUS must do the same.
To assist installers in this task, Inim provides several BUS isolator versions.
The standard version (IB200/P e IB200/U) protects and regenerates the BUS data signals.
The enhanced version (IB200/A) protects and regenerates the BUS data signals and its power supply.
Using an isolator limits BUS trouble caused by eventual anomaly (short-circuit, tamper) to the isolator-protected section and simplifies identification of it the section involved. As a result of the regeneration feature, fitting an isolator to the BUS also allows you to extend its length.
The IB200/A is also useful safeguard against acts of vandalism acts to peripherals located in non-protected areas. If a peripheral is damaged and the operating capacity of the BUS is at risk, the isolator, installed in the protected area will guarantee the functionality of the rest of the system.
Main features | |||
IB200/U |
IB200/P |
IB200/A |
|
Cable length downstream of the isolator (L) | 500 m @ 38.4 Kbps 350 m @ 125 Kbps 200 m @ 250 Kbps | 500 m @ 38.4 Kbps 350 m @ 125 Kbps 200 m @ 250 Kbps | 500 m @ 38.4 Kbps 350 m @ 125 Kbps 200 m @ 250 Kbps |
Maximum number of isolators in cascade | 9 @ 38.4 Kbps 6 @ 125 Kbps 2 @ 250 Kbps | 9 @ 38.4 Kbps 6 @ 125 Kbps 2 @ 250 Kbps | 9 @ 38.4 Kbps 6 @ 125 Kbps 2 @ 250 Kbps |
Galvanic isolation of data (D, S) |
Yes |
Yes |
Yes |
Regeneration of data signals (D, S) |
Yes |
Yes |
Yes |
Tamper signaling |
- |
Yes |
Yes |
I-BUS analysis function |
Yes |
Yes |
Yes |
Address programmable (for firmware upgrading) |
Yes |
Yes |
Yes |
Galvanic isolation of power supply (+, -) |
Configurable |
Configurable |
Yes |
Regenerated voltage of BUS power supply |
- |
- |
Yes |
Regenerated voltage of BUS power supply adjustable from 12 to 16 Vdc) |
- |
- |
13,8 Vdc |
Maximum regenerated current (@13.8Vdc) |
- |
- |
1000 mA |
Permitted interval of input voltage |
- |
- |
8-16 Vdc |
Dimensions (HxWxD) |
59x108x20 mm |
80x126x27 mm |
171x80x27 mm |
Weight |
60 g |
100 g |
170 g |