Ivy
Self-powered sounder/flasher for outdoor installation
Ivy is easy to program and even easier to install, these units boast unmatched features and performance.
The external heavy duty cover swings down on easy-to-free hinge projections (located on the both sides of the backplate) to provide a practical tool ledge. A metal inner-shroud protects all the components and reinforces the casing.
New-generation Light-Emitting-Diode technology provides super-bright flasher signals and allows extra-low power consumption. The units also provide two status LEDs, positioned at the sides of the flasher. The sounder can be programmed to generate different audible signals, thus allowing users to identify different types of alarms and/or locate the place of alarm.
The units offer many programmable parameters for maximum application flexibility, such as: Maximum alarm time, Input polarity, Flash frequency per minute, Trigger signal, etc.
Two models are available: Standard and BUS.
In the “Standard” model alarms are triggered by power cut or by the activation of the ancillary START input.
The “BUS” model connects to the SmartLiving BUS and is supervised and managed by the control panel. This direct-connection approach greatly simplifies wiring and system programming. In addition, it consents to the activation of event-related signaling (different signals for different events) programmed through the control panel.
The IVY series self-powered sounder/flasher units are a stylish, highly efficient way of rounding off an antintrusion control system.
Easy to program and even easier to install, these units boast unmatched features and performance.
The external heavy duty cover swings down on easy-to-free hinge projections (located on the both sides of the backplate) to provide a practical tool ledge. A metal inner-shroud protects all the components and reinforces the casing. New-generation Light-Emitting-Diode technology provides super-bright flasher signals and allows extra-low power consumption.
The units also provide two status LEDs, positioned at the sides of the flasher. The sounder can be programmed to generate different audible signals, thus allowing users to identify different types of alarms and/or locate the place of alarm.
The units offer many programmable parameters for maximum application flexibility, such as: Maximum alarm time, Input polarity, Flash frequency per minute, Trigger signal, etc.
Two models are available: Standard and BUS.
In the “Standard” model alarms are triggered by power cut or by the activation of the ancillary START input.
The “BUS” model connects to the SmartLiving BUS and is supervised and managed by the control panel. This direct-connection approach greatly simplifies wiring and system programming. In addition, it consents to the activation of event-related signaling (different signals for different events) programmed through the control panel. The BUS connection allows the control panel to supervise tamper, low-battery and fault signals and also the battery and input-voltage levels. All units are equipped with a test circuit that allows them to spot and report fault conditions instantly to the control panel. They are also protected against dislodgement, forced opening, wire cutting and blow torch tamper.
The Ivy/F model has an extra foam-tamper protection provided by the internal infrared circuitry of the loudspeaker. The system structure provides maximum rejection of false alarms. The Ivy series Sounder / Flasher units are also available in a “metal look” version.
Main features | ||
Standard model |
“BUS” model • |
|
Power supply |
13,8Vdc |
13,8Vdc (from I-BUS) |
Alarm trigger |
Power input |
On BUS, with characteristics in accordance with the event |
Ancillary trigger input |
START input |
On BUS |
Alarm lock for maintenance |
STOP input |
On BUS |
Ancillary signal LED trigger |
LED input |
On BUS |
Fault signal |
FAULT output |
On BUS |
Tamper signal |
Relay with voltage-free contact |
On BUS |
Separate audibe and visual signaling |
- |
Yes |
Volume adjustment |
- |
Yes |
Power-voltage reading |
- |
Yes |
Battery-voltage reading |
- |
Yes |
Temperature reading |
- |
Yes |
Dislodgement and Open-casing tamper protection |
Yes |
Yes |
Blow-torch tamper protection |
Yes |
Yes |
Foam tamper protection (“F” model only) |
Yes |
Yes |
Metal inner-shroud |
Yes |
Yes |
Super bright LED technology flasher |
Yes |
Yes |
On-unit sounder/flasher parameter programming |
Yes |
Yes |
Sound emission @ 3m. |
103dBA |
103dBA |
IP34 rating |
IP34 |
IP34 |
Dimensions (HxWxD) |
288x207x106 mm |
288x207x106 mm |
Weight |
2,7 Kg |
2,7 Kg |
• Compatible with SmartLiving panels from version 3.00.
Self-Powered Ivy Standard
Ivy: self-powered sounder/flasher for outdoor installation.
Ivy-F: self-powered sounder/flasher for outdoor installation with foam-tamper protection.
Ivy-M: self-powered sounder/flasher for outdoor installation, metal look.
Ivy-FM: self-powered sounder/flasher for outdoor installation with foam-tamper protection, metal look.
Self-Powered Ivy Bus
Ivy-B: self-powered sounder/flasher for outdoor installation with BUS interface feature.
Ivy-BF: self-powered sounder/flasher for outdoor installation with foam-tamper protection and BUS interface feature.
Ivy-BM: self-powered sounder/flasher for outdoor installation, metal look with BUS interface feature.
Ivy-BFM: self-powered sounder/flasher for outdoor installation with foam-tamper protection, metal look with BUS interface feature.